Safe Handling of Anhydrous Ammonia (NH3)

Ammonia Picture by Chemicalinterest

Objective:

To incorporate adequate safety precautions when working with or transporting NH3.

Background:

Personal protection is the responsibility of both the employer and the employee. Anhydrous ammonia is a strong alkali that can cause death or severe injury to body tissue due to its caustic, corrosive, freezing and dehydrating action. An almost instant freeze-drying process occurs when the liquid NH3 comes in contact with body tissue. Ample Water Supply for Flushing Eyes/Skin

  • Five gallons of water must be carried in each vehicle used to tow NH3.
  • Each employee should carry a full 16 oz. water bottle.
  • A 150 gallon water container should be kept at the loading site.

Personal Protective Equipment Necessary For Working With NH3

  • Goggles/face shield
  • Approved respirator
  • Rubber gloves
  • Long-sleeved and loose fitting shirts

Ammonia tank Author: NASA/holmgrar

Care and Maintenance of NH3 Tank

To handle NH3 safely, it is imperative that all equipment is properly maintained and checked daily. A regular, scheduled maintenance program will ensure that all the valves and the tank are safe for handling the high pressure liquid and its vapor form. Perform a daily visual inspection to locate any defects in the tank or hoses. Important Valves And Components List

  • Liquid Withdrawal Valve-Be sure valves are functional and will shut off. Any leak detected in the valve is cause for immediate repair or replacement. The valve should be removed every five years and inspected for internal corrosion and thread deterioration. At this time, check the excess flow for (1) movement of the valve plunger, (2) corrosion of springs, valve seat and guide, and (3) out of round disk.
  • Liquid Fill Valve-( Same inspection procedure as liquid withdrawal valve).
  • Vapor Return Valve-(Same inspection procedure as liquid withdrawal valve).
  • Pressure Gauge-Check the consistency with other tanks of similar volume. Make sure the lens is clean and the dial face is clearly readable.
  • Fixed Liquid Level Gauge-Clean, repair or replace as needed.
  • Liquid Level Float Gauge-Check against the 85% level gauge for accuracy. An inaccurate reading,leaking at the seal, or unreadable lens should be repaired or the defective item replaced.
  • Safety Relief (SR) Valve-Stand to one side and use a mirror for viewing. The SR valve should be free of dirt and rust. Replace the rain cap if it is damaged or missing. Leakage or discharge below 250 psi is cause for replacement. The SR valve should be replaced every five years.
  • Hydrostatic Relief (HR) Valve-Inspect the valve for leakage, corrosion or damage. The HR valve should be replaced every five years.
  • Transfer Hose-Examine the hose closely for cuts, abrasions, soft spots, bulges, kinking or flattening and similar defects. Check for slippage of the hose at coupling. The hose must be replaced five years from the date of manufacture (stamped on hose).
  • Tank Condition-Prevent corrosion and excessive pressure buildup from direct sunlight by keeping the tank painted with a reflective paint. Dented or damaged tanks should be taken out of service until checked by an authorized inspector and repaired as necessary. All welding on the tank must be done by a certified welder. Be careful in repairing or replacing these parts to prevent accidental exposure to anhydrous ammonia.

Checklist for Safety:

  • Do not fill the NH3 tank more than 85% full.
  • Do not use a faulty hitch pin or a wagon with a weak tongue.
  • Check the condition of the tires and frame of the tank.
  • Always disconnect the fill hose before removing the tank.
  • Replace deteriorated or out of date hoses and faulty valves. Hoses must be replaced within five years of the date stamped on the hose.
  • Always wear the proper protective equipment (as noted above).
  • Bleed prssurized NH3from the hose before connecting or disconnecting.

Review the Following Points

  • Have an ample water supply.
  • Wear personal protective equipment.
  • Never fill a tank over 85% of the tank’s capacity.
  • Inspect and replace hoses and valves as needed.
  • Bleed off pressure in the hose before disconnecting.
  • Stay clear of hose and valve openings.
  • Follow step-by-step procedure when using the equipment.